Specification:
Universal Integrated Furnace Control offers universal compatibility and diagnostics. It replaces a large number of furnace control models in single-stage warm air furnaces. Uses 120Vac hot surface igniter. Includes instructions and special wire harnesses for easy replacement.
Appliance operation/safety requirements controlled via microprocessor.
Controls circulating fan motor based on appliance requirements, in response to a conventional low voltage thermostat.
LED system status, performance and diagnostic indication.
Twinning capability
Item Type: Product
Frequency: 60 Hz
Operating Humidity Range (% RH): 0% to 95% non-condensing
Operating Temperature Range (F): -40°F to +175°F
Operating Temperature Range (C): -40°C to +79°C
Flame Failure Response Time (sec): 2 Seconds max @ 1µA
PrePurge: 30 seconds
PostPurge: 15 seconds
Cool Fan On Delay: 5 seconds
Cool Fan Off Delay: 0 or 60 seconds
Line Voltage: 120 Vac (97-132 Vac)
Low Voltage: 24V (18-30 Vac)
Igniter Current: 5 A resistive @ 120VAC
Thermostat Anticipator Setting (Stage 1 only): 100mA
HSI Warmup Time: 17/27 or 30/30 seconds
Trial For Ignition: 4, 6, or 8 seconds
Interpurge: 60 seconds
Ignition Trials: Three, two tries if flame is not sensed
Number of LEDs: 3
Heat On Fan Delay: 30 or 60 seconds
Heat Off Fan Delay: 60, 90, 120, or 180 Seconds
Gas Control Used With: Any 24Vac redundant, direct ignition gas control rated at 1.5A or less. Honeywell VR8205 recommended.
Cooling Contactor Used With: Any 24Vac contactor rated at 1.0A or less
Induced Draft Blower Load: 2.2FLA / 25LRA max @120Vac
Circulator Load: 14.5FLA / 25LRA max @120Vac
Type of Fan Used With: Standard Induction-Type Circulating Fan
Features:
Cross reference and wire harnesses provided for simple replacement over 195 existing furnace controls.
Main burner ignition using a 120V hot surface igniter.
Flame rectification circuit to monitor flame presence.
Monitoring of system pressure switch, high temperature limit, and rollout functions.
Applications:
Fit For Single Stage Warm Air Furnace